Solar and wind generation profiles: abstract illustration of the daily output curve of a solar plant and the output of a wind farm on one day

Solar and Wind Generation Profiles: Daily and Seasonal Patterns

Lukas Duldinger, CFA, RVA Lukas Duldinger, CFA, RVA
9 min read

Listen to article
Audio generated by DropInBlog's Blog Voice AI™ may have slight pronunciation nuances. Learn more

Table of Contents

What do solar and wind generation profiles look like? A solar plant follows the sun: its output rises after sunrise, peaks around midday and ends at sunset, and its summer months produce far more than its winter months. A wind farm follows the weather: it has no curve that repeats from day to day, and its strong season depends on the region. In the United States in 2025, the monthly capacity factor of the solar fleet ranged from 13.1% in December to 31.9% in June and July, and that of the wind fleet from 23.1% in September to 43.1% in March.

An annual production figure says how much energy a plant delivers in a year. A generation profile says when. The timing matters, because power prices, contracts and loan payments all have dates. This article shows the generation profiles of solar and wind for a day and for a year, explains why a mix of the two is steadier, and separates the part of production that repeats from the part that does not.

Generation profile and intermittency

The production of a solar plant or a wind farm has two parts.

  • The generation profile is the pattern that repeats: the curve of a clear day and the split of a year between its months. It holds the average of many years of weather.
  • Intermittency is the variation around that pattern. Clouds, calm spells and storms move the output, and no schedule announces them.

A profile tells you what to expect from July. It does not tell you what July 14 will bring.

The daily solar generation profile

The examples use two reference plants of the RVA Body of Knowledge. Solenta is a solar plant in southern Spain with 150 MWp of modules, 120 MWac of inverters and a production of 300 GWh a year. The wind farm has a capacity of 25 MW and produces 65,700 MWh a year.

Daily generation profiles of a solar plant and a wind farm: the solar plant on a clear summer day (1,200 MWh) and a clear December day (640 MWh), the wind farm on a windy, an average and a calm day

On a clear summer day, Solenta starts to produce after sunrise, reaches the 120 MW limit of its inverters at noon, holds it for five hours and falls back to zero at sunset. The day brings 1,200 MWh in 15 hours of production. On a clear December day the curve has the same form, but it is lower and shorter: 640 MWh in 10 hours.

Three things shape the solar day: the times of sunrise and sunset, the height of the sun, and the rating of the inverters. Modules on trackers widen the curve, because they follow the sun in the morning and in the evening. A plant with more module capacity than inverter capacity, such as Solenta, shows a flat top on clear days: the inverters cut off what exceeds their rating.

The daily wind generation profile

The daily generation profiles of solar and wind have little in common. A wind farm has no curve that repeats. Its output follows the weather systems that pass, and they can arrive at any hour of the day or the night. The right panel of the figure shows the 25 MW wind farm on three days.

DayEnergyCapacity factor of the day
Solar plant, clear summer day1,200 MWh41.7%
Solar plant, clear December day640 MWh22.2%
Wind farm, windy day504 MWh84.0%
Wind farm, average day180 MWh30.0%
Wind farm, calm day24 MWh4.0%

The capacity factor of a day is its energy divided by what the plant would produce at full output in all 24 hours. For the summer day of the solar plant that is 1,200 MWh ÷ (120 MW × 24 h) = 41.7%. The article on full load hours and capacity factor explains the measure.

Averaged over a season, a site can show a daily wind pattern, for example more wind at night. Such a pattern belongs to the site, and a single day can look entirely different. For a wind farm, the time of day says little. The weather says almost everything.

Seasonal generation profiles: solar and wind by month

The seasons change the picture again. Seasonal generation profiles show how the production of a year splits between its months. The figure and the table give the capacity factor by month of the solar and wind fleets of the United States in 2025, as reported by the U.S. Energy Information Administration.

Solar and wind capacity factor by month in the United States in 2025: solar from 13.1% in December to 31.9% in June and July, wind from 23.1% in September to 43.1% in March

Month of 2025Solar PVWind
January16.2%37.4%
February18.7%37.2%
March23.6%43.1%
April27.5%40.7%
May29.3%32.1%
June31.9%32.2%
July31.9%27.5%
August29.7%23.8%
September26.7%23.1%
October22.4%33.8%
November16.9%35.4%
December13.1%39.2%
Year 2025: solar PV 24.0%, wind 33.8%. Utility-scale plants, solar on the AC rating.

Solar follows the sun. Summer days are longer, and the sun stands higher in the sky. The solar fleet reached 31.9% in June and July and 13.1% in December, a ratio of 2.4. The farther a site lies from the equator, the larger the difference between its summer and its winter.

Wind follows the weather systems of its region. The wind fleet of the United States was strongest in March, at 43.1%, and weakest in September, at 23.1%, a ratio of 1.9. A wind profile belongs to a region and a site. It cannot be borrowed from another one.

This seasonality in solar and wind power generation repeats every year. That makes it far easier to plan for than the weather of a single day.

Solar and wind together: a steadier year

In the figure above, the two lines move against each other for most of the year. Where solar is weak, wind is strong. A portfolio that holds both therefore has a steadier year than either plant alone. The next figure compares the generation profiles of the two reference plants, as the share of the year's production that falls in each month.

Seasonal generation profiles as monthly shares of annual production: a solar plant from 5.0% to 12.0%, a wind farm from 4.8% to 13.0% and a mix of both from 7.6% to 9.1%

Solenta's best month holds 12.0% of its year and its worst 5.0%. The wind farm, at a site with windy winters, ranges from 13.0% in January to 4.8% in July. A mix with equal annual energy from each stays between 7.6% and 9.1% in every month.

Measured data show the same effect. For Germany, Fraunhofer ISE reports that monthly solar production deviates from its annual average by 53% on average and monthly wind production by 30%. For the sum of the two, the figure is 14%.

Steadier does not mean steady. A mix still varies from day to day, and a dark, calm spell affects both parts at once. German has a word for such a spell: Dunkelflaute.

From a profile to the production of a month

A financial model holds the seasonal profile as twelve shares, one for each calendar month, that sum to 100%. The production of a month is the annual production multiplied by the share of that month.

Production of a month = annual production × share of the month
300,000 MWh × 12.0% = 36,000 MWh

Solenta's July holds 12.0% of the year, which is 36,000 MWh. That is 40.3% of what 120 MW could deliver in the 744 hours of the month. December holds 5.0%, or 15,000 MWh, a capacity factor of 16.8%. The 28.5% of the full year is an average that the plant holds in no single month.

Two articles take the profile further. How to consider seasonality in Excel builds the twelve shares and the lookup by month. How to model the seasonality of renewable energy revenues takes the months through to revenue and debt service.

Enter a share and a capacity to see a month:

Calculator

Production and capacity factor of a month

Production of the month: 36,000 MWh
Capacity factor of the month: 40.3%
Average output: 48.4 MW · Per day: 1,161 MWh

Production = annual production × share of the month. Capacity factor = production ÷ (capacity × days × 24 hours).

Free PDF · The RVA Body of Knowledge

The complete curriculum of renewable energy project finance

42 readings in five topic areas, from power and energy to debt sizing and battery storage, with practice questions after every reading. The Complete Edition is free.

Get the Free PDF

No two years are alike

Generation profiles are averages, and single months and years deviate from them. The wind fleet of the United States shows by how much.

Wind, capacity factor20242025Change
January31.6%37.4%+18.4%
September26.9%23.1%−14.1%
Full year34.3%33.8%−1.5%

The two months moved by double digits, in opposite directions. The two full years differed by 1.5%. The longer the period, the more of the weather averages out, which is why a forecast for one month is far less certain than a forecast for a year. The article on P50 and P90 energy yields shows how that uncertainty is measured.

Volume risk and shape risk

Generation profiles also show a risk that an annual figure hides. A forecast can miss in two ways. The year can bring less energy than expected: that is volume risk. Or the energy can arrive at other times than expected: that is shape risk. A plant can end a year exactly on its forecast and still fall short in the quarter in which a loan payment is due, or in the hours that a contract asks for.

Who carries the shape risk depends on the contract. Under a pay-as-produced contract the buyer takes the energy as it comes. A baseload contract asks for the same delivery in every hour, so the producer has to buy what the plant does not deliver in a given hour. See pay-as-produced PPA vs. baseload PPA for the two forms.

Key takeaways: solar and wind generation profiles

  • A generation profile is the pattern of production in time: by hour of the day and by month of the year. Intermittency is the variation around it.
  • Solar follows the sun: a curve on every clear day, and far more production in summer than in winter.
  • Wind follows the weather: no daily curve, and a strong season that depends on the region.
  • A mix is steadier: the months of solar plus wind lie closer together than those of either one.
  • A model holds the profile as twelve shares that sum to 100%. Production of a month = annual production × share of the month.
  • A profile is an average. Single months deviate by double digits, full years by far less.

Practice questions

Three questions in the format of the RVA Body of Knowledge. Pick an answer to check it.

1. A solar plant produces 420,000 MWh a year. Its monthly profile gives March 9.5% of the year and January 4.5%. How much more does it produce in March than in January?

  1. 18,900 MWh
  2. 21,000 MWh
  3. 39,900 MWh
Show answer

B is correct. The two shares differ by 5.0 percentage points, and 420,000 MWh × 5.0% = 21,000 MWh. Option A is the production of January, 420,000 MWh × 4.5%. Option C is the production of March, 420,000 MWh × 9.5%.

2. A 40 MW wind farm produces 624 MWh on one day. A day has 24 hours. Its capacity factor for that day is closest to:

  1. 15.6%
  2. 26.0%
  3. 65.0%
Show answer

C is correct. At full output in every hour the farm would produce 40 MW × 24 h = 960 MWh, and 624 ÷ 960 = 65.0%. Option A divides the energy by the capacity, which gives 15.6 full load hours and not a percentage. Option B divides the energy by 24 hours, which gives the average output of 26 MW.

3. A portfolio holds a solar plant. It adds a wind farm at a site with windy winters that produces the same energy per year. What happens to the monthly production of the portfolio?

  1. It becomes steadier across the year, because the two seasons offset each other.
  2. It becomes more seasonal, because two seasonal plants add their swings together.
  3. It becomes the same in every hour, because wind fills the hours without sun.
Show answer

A is correct. The solar plant is strong in summer and the wind farm in winter, so the months of the mix lie closer together than those of either plant. Option B would hold only for two plants with the same season. Option C goes too far: a mix still varies from day to day, and a dark, calm spell affects both plants at once.

Free PDF · The RVA Body of Knowledge

The complete curriculum of renewable energy project finance

42 readings in five topic areas, from power and energy to debt sizing and battery storage, with practice questions after every reading. The Complete Edition is free.

Get the Free PDF

Go deeper

Sources: U.S. Energy Information Administration, Monthly Energy Review, November 2026, Table 7.8a (capacity factors of utility-scale plants by month, 2024 and 2025); Fraunhofer ISE, Recent Facts about Photovoltaics in Germany, version of August 20, 2026 (monthly deviation of solar and wind production). Figures checked on November 28, 2026. The plants in the examples are illustrative and come from the RVA Body of Knowledge.

FAQs

What is a generation profile?

A generation profile is the pattern of a plant's production in time: by hour of the day and by month of the year. It holds the part of production that repeats, as an average of many years of weather. A financial model uses the seasonal profile as twelve monthly shares that sum to 100%.

When does a solar plant produce the most electricity?

Around midday on clear days, and in the summer months. In the United States in 2025, the solar fleet reached a capacity factor of 31.9% in June and July against 13.1% in December (U.S. Energy Information Administration).

When do wind farms produce the most electricity?

That depends on the region. The wind fleet of the United States was strongest in March 2025, at a capacity factor of 43.1%, and weakest in September, at 23.1%. A site with windy winters peaks around January. A wind farm has no daily curve like a solar plant: its output follows the weather systems that pass.

Why are solar and wind called intermittent?

Because their output follows the weather and not a schedule. Clouds, calm spells and storms move the production around its profile, and no schedule announces them. Intermittency is the variation around the profile. The profile itself, such as more solar production in summer, repeats every year.

Do solar and wind complement each other?

Over the months of a year, they do. For Germany, Fraunhofer ISE reports that monthly solar production deviates from its annual average by 53% on average and monthly wind production by 30%, but the sum of the two by only 14%. A mix still varies from day to day, and a dark, calm spell affects both at once.

How do you calculate the production of a month from the annual production?

Multiply the annual production by the share of the month in the profile. A plant that produces 300,000 MWh a year with 12.0% of the year in July produces 36,000 MWh in July. The twelve shares of the profile must sum to 100%.

Series

Generation profiles, seasonality and degradation in four lessons

The series before this one: Capacity factor and energy yield in four lessons, on how much a plant produces in a year.

← Back to the Academy

Earn Your RVA Certification.

Become a world-class financial modeler within the renewable energy sector and push your career to the next level.